Search results for "Water cooling"
showing 10 items of 44 documents
Long-term performance and life cycle assessment of energy piles in three different climatic conditions
2020
Abstract The main purpose behind the use of energy piles is to enable the exploitation of geothermal energy for meeting the heating/cooling demands of buildings in an efficient and environment-friendly manner. However, the long-term performance of energy piles in different climatic conditions, along with their actual environmental impacts, has not been fully assessed. In this paper, the results of a finite element model taking into consideration the heating and cooling demands of a reference building, and the intermittent operation of a ground source heat pump, are revealed to examine the long-term performance of energy piles. Furthermore, a life cycle assessment model is implemented to com…
Technical Possibilities of Reducing the Sound Pressure Level Emitted into the Environment by a Power Transformer
2011
The subject presented in this paper refers to measurements and assessment of the corrected sound pressure level values (noise) occurring around a medium-power transformer. The paper presents the values of noise accompanying the operation of the power object before and after its modernization, which consisted in repeated core pressing and replacement of the cooling system. The main aim of the research work was the assessment of the influence of the repair work on the noise level emitted into the environment.
Monitoring results and analysis of thermal comfort conditions in experimental buildings for different heating systems and ventilation regimes during …
2017
This paper focuses on the long-term monitoring of thermal comfort and discomfort parameters in five small test buildings equipped with different heating and cooling systems. Calculations of predicted percentage of dissatisfied people (PPD) index and discomfort factors are provided for the room in winter season running three different heating systems – electric heater, air-air heat pump and air-water heat pump, as well as for the summer cooling with split type air conditioning systems. It is shown that the type of heating/cooling system and its working regime has an important impact on thermal comfort conditions in observed room. Recommendations for the optimal operating regimes and choice o…
Are urban water bodies really cooling?
2020
Abstract Small urban water bodies, like ponds or canals, are often assumed to cool their surroundings during hot periods, when water bodies remain cooler than air during daytime. However, during the night they may be warmer. Sufficient fetch is required for thermal effects to reach a height of 1–2 m, relevant for humans. In the ‘Really cooling water bodies in cities’ (REALCOOL) project thermal effects of typical Dutch urban water bodies were explored, using ENVI-met 4.1.3. This model version enables users to specify intensity of turbulent mixing and light absorption of the water, offering improved water temperature simulations. Local thermal effects near individual water bodies were assesse…
Real-time simulation and control system for the continuous casting process
2005
In this paper we present a real-time system which is used to simulate the unsteady-state continuous casting process and to control the secondary cooling water sprays. The aim of the control system is to keep the surface temperature of the slab constant with respect to time in spite of casting speed variations, and in this way minimize the formation of cracks in the final product. The simulator calculates the temperature distribution using a mathematical model based on a heat conduction formula with phase changes. The optimal spray water flow rates for each spray cooling zone will be calculated by minimizing the deviation between the target surface temperature and the calculated actual surfa…
Nonsmooth Penalty Techniques in Control of the Continuous Casting Process
1991
We introduce a mathematical model which is used to simulate the continuous casting process and to control the secondary cooling water sprays. The main object is to minimize the defects in the final products. The problem is formulated as an optimal control problem where the cost function is constructed according to certain metallurgical criteria and constraints. The temperature distribution of the strand is calculated by solving a nonlinear heat equation with free boundaries between solid and liquid phases.
Design, construction and cooling system performance of a prototype cryogenic stopping cell for the Super-FRS at FAIR
2015
A cryogenic stopping cell for stopping energetic radioactive ions and extracting them as a low energy beam was developed. This first ever cryogenically operated stopping cell serves as prototype device for the Low-Energy Branch of the Super-FRS at FAIR. The cell has a stopping volume that is 1 m long and 25 cm in diameter. Ions are guided by a DC field along the length of the stopping cell and by a combined RF and DC fields provided by an RE carpet at the exit-hole side. The ultra-high purity of the stopping gas required for optimum ion survival is reached by cryogenic operation. The design considerations and construction of the cryogenic stopping cell, as well as some performance character…
ADVANCED SOLAR ASSISTED DESICCANT AND EVAPORATIVE COOLING SYSTEM EQUIPPED WITH WET HEAT EXCHANGERS
2011
Abstract This work concerns an innovative solar assisted desiccant and evaporative cooling (DEC) system for building air conditioning. In this system, air-to-air packaged wet heat exchangers are used to maximize the exploitation of the evaporative cooling potential associated with the exhaust air stream. The thermodynamic cycle is first theoretically described, and then an example of a real application is shown. The system presented is an experimental DEC system originally installed at the beginning of 2008 at the Solar Laboratory of the University of Palermo and recently modified and updated. These modifications have been implemented with the aim to foster some problems related to the conv…
Lessons learned with the SAGE spectrometer
2012
The SAGE spectrometer combines a high-efficiency γ-ray detection system with an electron spectrometer. Some of the design features have been known to be problematic and surprises have come up during the early implementation of the spectrometer. Tests related to bismuth germanate Compton-suppression shields, electron detection efficiency and an improved cooling system are discussed in the paper.
Thermal comfort condition assessment in test buildings with different heating/cooling systems and wall envelopes
2017
Abstract The main aim of this study is a comprehensive analysis of long-term monitoring data of thermal comfort and discomfort parameters in small identical test buildings equipped with different heating/cooling systems. Calculations of PPD index expressed the human perception of thermal comfort and such discomfort factors like draught rate and vertical air temperature difference are provided for the room in winter season running three different heating systems – electric heater, air-air heat pump and air-water heat pump, as well as for the summer cooling with split type air conditioning systems. It is shown that the type of heating/cooling system and its working regime has a significant im…